Troubleshooting - Page 2
Q
A
Q
A
PowerCost Monitor
Q
A
Q
A
Q
A
Q
A
The power usage shown on my Display Unit is not updating or is
unusually low.
Try turning on an electric appliance that consumes a large amount of power
such as a stove or dryer. If the values on the Display Unit do not start to update
within a few minutes, then the Sensor Unit is likely not aligned correctly on
your utility meter. Try repeating the appropriate alignment steps described in
the Installation Guide.
The temperature shown on the Display Unit does not match weather
reports or appears to be incorrect.
The temperature shown on the Display Unit is the ambient temperature at your
utility meter; it may vary from other sources, such as TV weather reports, because
of distance and other factors. Also, if your utility meter is exposed to direct
sunlight during any part of the day, then the reading will be higher than normal.
The reading will return to the correct value when the utility meter is in the shade.
My Display Unit behaves erratically and shows illogical values.
Should your Display Unit start displaying any unexpected values, reset it to the
factory settings by pressing on the PROG/SYNC and CLEAR keys simultaneously
until you hear 3 beeps (about 5 seconds). However, doing so will erase all your
existing rate entries and you will have to follow the instructions in Steps 6 and 7
of the Installation Guide to setup your Display Unit again.
The consumption information shown on my Display Unit is not correct
and it jumps randomly.
Several factors can affect the accuracy of the information shown on your Display
Unit and they all relate to interference. If your neighbour also has a PowerCost
Monitor system, you may be receiving their information. In this case, you need
to change the Sensor Unit address and resynchronize the Display Unit. Repeat
Step 10 in the Installation Guide, but press and hold the RESET button for five (5)
seconds. The Sensor Unit then selects a new address randomly on which to base
the synchronization.Wireless devices, such as weather stations or old-style baby
monitors and cordless phones, transmit information on frequencies similar to
the PowerCost Monitor. If you have a wireless weather station try turning it off
briefly and check to see if the PowerCost Monitor Display Unit returns to normal
operation. If it does, then check to see if you can change the weather station’s
operating channel.
My display Unit is showing SLEEP and dashes. What do I do?
This means that your Display Unit has stopped receiving the signal from your
Sensor Unit for more than 10 minutes. Go to your Sensor Unit, taking the Display
Unit with you. Remove the batteries from the Display Unit and put them back in.
After a few seconds, press PROG/SYNC unil you hear two beeps to put the Display
Unit in ID mode, then press the RESET button on the Sensor Unit. Normal
operation should resume.
The total shown on my Display Unit does not match the total shown
on my electricity bill.
In order for the two totals to match, you would need to clear the totals on the
Display Unit on the exact day and time the utility company reads your meter. In
addition, your electricity bill also may include other fees, as well as any applicable
taxes. The total amount shown on the PowerCost Monitor is accurate, but is
really meant as a reference to indicate how much power you have consumed since
you last cleared the totals. For example, if you clear the totals at the beginning of
every monthly cycle, then you can use the PowerCost Monitor to compare against
your monthly budget.
© 2008. Blue Line Innovations Incorporated.
All rights reserved. Information in this
document is subject to change without notice.
Blue Line Innovations and PowerCost Monitor
are trademarks of Blue Line Innovations
Incorporated. All other trademarks are the
property of their respective owners.
Printed in China. PN BLI-00299R001
Blue Line Innovations Inc.
187 Kenmount Road
1st Floor, ICON Building
St. John’s, NL Canada
A1B 3P9
www.bluelineinnovations.com
Toll Free: 1-866-607-2583