Determine Your Meter Type and Power Factor
In some cases, it may be necessary to adjust your Sensor Unit to fit your particular
meter. Therefore, it is extremely important to determine exactly what kind of meter is
installed on your premises.
INSTRUCTIONS: To determine your meter type, study the illustrations and
descriptions below.
1.
Locate your electricity meter.
2.
Determine which of the following illustrations most closely matches your meter.
Remember your meter type.
3.
Find your meter’s power factor and write it down in the box labeled “Power Factor”
next to the illustration below which matches your meter. Your meter’s power factor
is indicated on the face of the meter, most often next to the letters Kh (less often the
letters Ks or Kt). In most cases, your meter’s power factor is 7.2 if it has dials and a
spinning disk, or 1.0 if it has a digital readout.
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
Type 1 Meter: Electromechanical
This type of meter has dials and a spinning disk.
The Sensor Unit reads the revolutions of the disk
and transmits that information to the PCMWiFi unit.
Type 3 Meter:
Electronic with optical port on the face,
less than 1.5 inches from the outer rim
On these electronic meters, the optical port is on the
face, located less than 1.5 inches (37 mm) from the
meter’s outer rim.
If in doubt, measure the distance using the ruler below.
This type of meter requires that you mount the supplied
rubber shims on the underside of the Sensor Unit.
Type 4 Meter:
Electronic with optical port on the top
On this type of meter, the optical port is located on
the top portion of the meter.
This kind of meter requires you to reconfigure the
Sensor Unit and install the Clear Alignment template.
Type 2 Meter: Electronic with optical port on
the face, 1.5 inches or more from the outer rim
On this type of meter, the optical port is located at least
1.5 inches (37 mm) from the meter’s outer rim.
If in doubt, measure the distance using the ruler below.
NOTE: The optical port can be located at either the right
(3 o’clock), or left (9 o’clock) position on your meter.
Power Factor
Power Factor
Power Factor
Power Factor
3
PowerCost Monitor
Installation Guide
Welcome
Congratulations on your purchase of the PowerCost Monitor™, a new electricity-
monitoring device that informs you in real time of the amount of electricity your
household is consuming. This Guide explains how to get your system ready for
use. Please follow the instructions in the order shown without skipping any steps.
Important Safety Precautions
Install your PowerCost Monitor Sensor Unit on a dry day and take all necessary
safety precautions, particularly if you need to use a ladder for installing the
Sensor Unit. In addition, please read and apply the safety instructions below
at all times.
Do not immerse either PowerCost Monitor unit in any liquid.
Do not drop or cause any sudden impact to either PowerCost Monitor unit.
If disposing of the PowerCost Monitor, do so in accordance with your local
waste disposal regulations.
Take precautions when handling batteries. They can cause injuries, burns,
and/or property damage as a result of contact with metal objects, heat, and
corrosive materials.
Read all the instructions carefully before using your PowerCost Monitor.
Verify the Contents of the Box Configure the WiFi Bridge
1 4
Verify that your box contains all these components. If any item
is missing, please contact your PowerCost Monitor reseller.
PowerCost Monitor
Installation Guide
Welcome
Congratulations on your purchase of the PowerCost Monitor™, a new electricity-monitoring
device that informs you in real time of the amount of electricity your household is consuming.
This Guide explains how to get your system ready for use. Please follow the instructions in the
order shown without skipping any steps.
Important Safety Precautions
Install your PowerCost Monitor Sensor Unit on a dry day and take all necessary safety
precautions, particularly if you need to use a ladder for installing the Sensor Unit. In addition,
please read and apply the safety instructions below at all times.
Do not immerse either PowerCost Monitor unit in any liquid.
Do not drop or cause any sudden impact to either PowerCost Monitor unit.
If disposing of the PowerCost Monitor, do so in accordance with your local waste
disposal regulations.
Take precautions when handling batteries. They can cause injuries, burns, and/or property
damage as a result of contact with metal objects, heat, and corrosive materials.
A damaged LCD display may leak fluids that can be harmful to your health. If any fluid
leaks from the Display Unit after you drop it accidentally, immediately wash it off with
soap and water.
Read all the instructions carefully before using your PowerCost Monitor.
Verify the Conte nts of the Box
1
Verify that your box contains all these components. If any item
is missing, please contact your PowerCost Monitor reseller.
ST
A
T
U
S
R
E
S
E
T
+
_
+
_
+
_
+
_
Rubber Shim
Alkaline “AA” Batteries
Installation Guide
and User Guide
Display
Unit
Sensor Unit
(with clamping strap)
Clear Alignment Template
STAT
U
S
R
ESET
+
_
+
_
Rubber Shim
2 Alkaline “AA” Batteries
Installation Guide
Sensor Unit
(with clamping strap)
Clear Alignment
Template
ruler
Install the Batteries in the Sensor Unit
2
Turn the screw counter-
clockwise to open the Sensor
Unit battery compartment
cover.
Insert two AA batteries in the
orientation indicated by the +
and – signs printed on the
circuit board, then close and
lock the battery compartment
by turning the screw clockwise.
Do not overtighten. The red
STATUS indicator should
illuminate within 10 seconds.
DO NOT remove the grease from around
the battery lid. This grease helps protect
the internal components from moisture.
Type 1 Meter: Electromechanical
1
Open the Sensor Arm latch
G
by pulling upward.
2
Extend the Sensor Arm
B
to its full length by pulling
on it firmly, but gently. If you accidentally pull it out
completely, push it back into the casing.
3
Close the latch
G
.
Type 2 Meter: Electronic with optical
port on the face, 1.5 inches or more from
the outer rim
1
Open the Sensor Arm latch
G
by pulling upward.
2
Ensure that the Sensor Arm
B
is pushed in as far
as it will go into the body of the Sensor Unit.
3
Close the latch
G
.
Type 4 Meter: Electronic - optical port on top
1
Open the Sensor Arm latch
G
by pulling upward.
2
Gently pull the Sensor Arm
B
completely out of the Sensor Body.
3
Turn over the Sensor Arm
B
.
4
Push the thin end of the Sensor Arm
B
upwards through the latch opening and press
the Sensor Arm firmly into the cavity.
5
Firmly push the Sensor Head
C
behind the strap, and as far down as it will go into the
bottom cavity of the body. The dark Sensor Head
LED
D
must be clearly visible below
the clamp. If necessary, use a dull pointed object, such as a ballpoint pen to push the
head
C
downwards.
6
Tuck the wire
E
into the side cavity
F
.
7
Close the latch
G
.
A
B
C
D
E
F
G
Type 3 Meter: Electronic with optical port on the face, 1.5 inches
maximum from the outer rim
1
Perform the same steps as described for a Type 2 meter.
2
Peel off the adhesive backing from the shim.
3
Position the shim on the underside of the Sensor Unit casing with the adhesive side down.
4
Press the shim in place onto the underside of the Sensor Unit casing.
4
Clamp
Sensor Arm (pulled out)
Sensor Head
Sensor LEDs
(dark and white)
Wire
Wire Cavity
Sensor Arm Latch
Instructions: Perform the operations in the block that corresponds to your meter
type. When you are done, go to Step 9 - Install your Sensor Unit.
A
B
C
D
E
F
G
Prepare Your Sensor Unit
5
AC adaptor
USB cable
PowerCost Monitor
WiFi (PCM WiFi)
D Configuring the WiFi Bridge
STEP 1: UPDATING THE DEVICE SOFTWARE
The installation wizard will verify the software version in your PCM WiFi device.
If your device requires updating the Wizard will inform you and let you know if
1 or 2 updates will be required. During the updating process you may be
prompted to disconnect and reconnect the USB cable.
It is very important to disconnect the cable only when prompted to do
so during the process. Disconnecting the USB cable at the incorrect time
during the update process can render your device inoperative.
Follow the on-screen instructions to complete the software update. When the
update is complete click NEXT.
STEP 2: CONFIGURE THE WIRELESS SETTINGS
Using the information from Step A of this section enter the name of your wireless
network (SSID), your security type and your passphrase (if not using Open
Security). If you do not know this information you can obtain it from the wireless
setting section of your router. If you are unsure of how to obtain this information
please contact the person who initially configured your router. Once you have
entered the settings for your wireless network click NEXT.
STEP 3: SET YOUR ELECTRICITY METER POWER FACTOR
Using the information you collected in Section 2 (Determine Your Meter Type and
Power Factor), enter the Power Factor value for your meter. The PCM WiFi bridge
device uses this value to correctly calculate your energy usage. This value must be
between 1.0 and 99.9. After entering this number click NEXT.
STEP 4: PAIRING THE PCM WIFI AND SENSOR
Disconnect your PCMWiFi device and move it to a permanent indoor location
as close as is practical to your electricity meter. After connecting the AC adapter
wait 30 seconds then press the SYNC button on top of the unit for approximately
6 seconds until the status LED turns solid red. Release the SYNC button, then
return to your sensor unit and press and release the RESET button on the sensor.
Click NEXT on your computer.
B Connect Your Hardware
It is recommended that you setup your PCM WiFi device from a PC that is using a
wireless connection. This will assist in determining your network configuration.
1. Plug the AC adaptor into the wall and then into the PCM WiFi device.
2. Plug the PCM WiFi device into your computer using the USB cable provided.
You may or may not receive a “New Hardware Found” message from
Windows. If you do, Windows may want to restart after you connect your
device for the first time. Restart you computer if prompted to do so, before
proceeding to Step C.
Note: The status LED on your PCM WiFi device will alternate between
RED and GREEN while connected to your computer
C Download Your PCM WiFi Software
The PCM WiFi unit requires software to configure its wireless features.
To install, follow the steps below:
1. Open your Internet browser and type in:
http://www.bluelineinnovations.
com/Downloads/PCMWiFi/iris/publish.htm
2. After accepting the license agreement click INSTALL to download the PCMWiFi
software.
3. Follow the on-screen instructions for downloading and installing the
PCM WiFi Setup Wizard
.
A Before Proceeding
Before attempting to configure
the WiFi bridge device ensure that
your wireless router is configured
to allow 802.11b protocol and that
Access” or “MAC” filtering is
disabled. If you are unclear about
these settings please see the FAQs
section at the end of this document
or contact the person who initially
configured your router.
Record your router’s wireless settings here:
Network name (SSID):
Passphrase:
Security type:
Open
WEP
WPA/WPA2
or
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - PowerCost Monitor

Determine Your Meter Type and Power FactorIn some cases, it may be necessary to adjust your Sensor Unit to fit your particular meter. Therefore, it is

Seite 2 - Technical Specifications

8Install Your Sensor Unit Frequently Asked Questions6START – Read SAFETY PRECAUTIONS firstIMPORTANT: Turn on a high energy-consuming appliance in your

Kommentare zu diesen Handbüchern

Keine Kommentare